Game Info
-The purpose of this app is to provide guidance and perform calculations for electrical installations industry.
-The app offers step-by-step guidance for engineering calculations, providing results for cable, breaker, earthing, PFC, and trunk size.
-The computations adhere to British Standards (BS) and are presented in metric units.
-The outcomes and calculations can be generated in PDF format, allowing for easy sharing and saving in the mobile file directory.
Cables & Breaker Page:
-The purpose of this calculator page is to determine the appropriate standard copper cable size, circuit breaker, or fuse size based on the provided load value in accordance with IEE Wiring Regulation BS 7671.
-This page enables users to input installation conditions and ambient factors step by step. The objective is to precisely identify deration factors influenced by circuit breaker type, ambient temperature, grouping spaces, etc.This data is essential for calculating current capacities using tabulated values from appendix 4, considering the chosen installation method and cable types, ultimately determining the appropriate standard breaker size rating and cable size.
-Voltage drop is taken into account when selecting circuit breakers and cable sizes.
-The result includes formulas, a step-by-step calculation guide, and references for your convenience.
NOTE: Clicking the Calculate button may result in a delay, especially on older mobile devices, as the calculation process and reference table search take some time. However, it''s only slightly less than a minute, so please be patient.
Earthing Page:
-The purpose of this calculator page is to pre-determine the estimated length of earth rods and quantity or mesh strip length and size following the guidelines of BS 7430:2011.
-This page provides immediate selection results, detailed table along with step-by-step calculation formulas and the soil resistivity chart.
-Additionally, this calculator page can produce a soil resistivity report by utilizing soil resistance measurements obtained through the four-probes Megger tool, commonly known as the Wenner method.
Trunk Sizing Page:
-The purpose of this calculator page is to determine the metal trunk size needed to accommodate a group of standard wires, considering capacity factors outlined in tables 5E and 5F in BS 7671/Appendix 5.
-This page provides immediate selection results, along with a comprehensive table and occupancy capacity charts.
-The installed wires cross sectional areas in a trunk shall not exceed 45% of trunk internal cross sectional area which is taken into account as in BS 7671.
PFC Page:
-The purpose of this calculator page is to determine the right size of capacitor bank in kVAR reactive power “Q” and Microfarad “µF” for power factor compensation.
-This page provides immediate Capacitor Bank selection results, along with detailed Power Triangle parameters with calculations.
-Capacitive loads have an opposite effect on the electrical system to inductive loads, so introducing a capacitor to an inductive system can improve the power factor.
-Good power factor would lead in better electricity efficiency hence low cost of bill.
Games Related to Electrical Installations
How to Download and Play Electrical Installations on PC
- 1Download and install LDPlayer X on your PC.
- 2Enter and search for Electrical Installations in the search bar at the top left corner.
- 3Click on "Install" to download Electrical Installations automatically.
- 4Once the installation is completed, click on "Open".
- 5The game will be launched in LDPlayer automatically. Enjoy!
- 6You can also click on the game icon of Electrical Installations in LDPlayer homepage to start playing.
Advantages of Playing Electrical Installations on PC with LDPlayer X
Wider Screen
The larger PC screen allows you to capture clearer visual details in Electrical Installations.
Customized Control
Play games with mouse, keyboard & controller with your own customized setting, guaranteeing a gaming experience for Electrical Installations comparable to actual PC gaming.
Multi-instance & Synchronizer
Log in to multiple game accounts or play multiple games at the same time. A great time saver for rerolling.
Higher FPS
With more realistic and smooth visual effect, and more coherent action, visual experience and the sense of immersion for Electrical Installations is greatly optimized.
Game Assistant
Use scripts to simplify complex task processes and complete tasks automatically. Enjoy your game with ease.
Video Record
Record highlights or operation processes in Electrical Installations to share with your friends.
Computer Configuration for Electrical Installations PC Version
System
Win10 64-bit or higher, including OpenGL 4.xSystem
Win7 / Win8 / Win8.1 / Win10CPU
8th Gen Intel Core i3-8100 4-core or higher, with VT enabledCPU
Intel or AMD CPU Processor x86 / x86_64, with VT enabledGPU
NVIDIA GeForce GTX1050 Ti 2GB or higherGPU
Windows DirectX 11 / OpenGL 4.0 Graphics DriverMemory
8GB or moreMemory
At least 2GB RAMStorage
10GB or more available space for installation disk, 2GB or more available space for system diskStorage
At least 1GB available memoryYou might also like
More popular games
Free Fire
PUBG MOBILE
Mobile Legends: Bang Bang
Among Us
Brawl Stars
Clash of Clans
GODDESS OF VICTORY: NIKKE
Call of Duty: Mobile Season 10
Free Fire MAX
PUBG MOBILE LITE
Minecraft: Play with Friends
CookieRun: Kingdom
Ragnarok M: Eternal Love
Epic Seven
Call of Duty®: Mobile - Garena
Roblox
Arknights
Ragnarok X: 3rd Anniversary
Clash Royale
Black Desert Mobile
Apex Legends Mobile
Electrical Installations - FAQ
Q: Is LDPlayer X safe for players?
Q: Can I play Electrical Installations on PC?
Q: Why is LDPlayer X the best platform to play Electrical Installations on PC?
The powerful built-in Android emulator lets you immerse yourself in every small detail of the game.
Additionally, it allows you to simply play numerous popular games in your browser, such as Brawl Stars and Roblox.
You can also enjoy the best top-up discount for popular games on LDShop.